This bulk cable features the Accu-Pull Measuring System: Descending sequential foot markings let you know exactly how much is left on the spool. No more guesswork or measuring to see how much cable you have left.
AC Leakage Current Through Overall Jacket — AC 1500 < 10 mA ACR (Minimum at 100-m) — 26.5 dB at 100 MHz; 7.5 dB at 250 MHz; 2.8 dB at 300 MHz Attenuation (Maximum at 100-m) — 19.8 dB at 100 MHz; 32.8 dB at 250 Mhz; 51.8 dB at 550 MHz Cable Type — 4-pair UTP, 300 V Capacitance Unbalance (Maximum) — 330pF/100-m (Pair to ground) Capacitance, Mutual Maximum — 56 pF/km Characteristic Impedance — 1-550 MHz: 100 +/- 15 ohms Cold Bend Test — -20°C at 4 hrs, no crack Conductor — 23 AWG, solid, bare copper Conductor Resistance — 93.8 ohm/67°F maximum Dielectric — AC: 1.5 KV/2 Sec DC Resistance Unbalance (Maximum) — 5% Delay Skew (Maximum) — 1-550 MHz: 30 ns/100-m EL-FEXT (Minimum at 100-m) — 27.8 dB at 100 MHz; 19.8 at 250 MHz; 12.9 at 550 MHz Insulation Material — HDPE; Thickness: Average and minimum: 0.008inch; Diameter: 0.039inch +/- 0.0011inch Insulation Shrinkback — 150 m/m; 121°C at 1hr at 9.5 m/m Jacket — 0.24inch OD NEXT (Minimum at 100-m) — 46.3 dB at 100 MHz; 40.3 dB at 250 MHz; 35.2 dB at 550 MHz Propagation Delay — 550 Mhz: 536 nS/100-m PS-ACR (Minimum at 100-m) — 24.5 dB at 100Mhz; 5.5 dB at 250 MHz PS-ELFEXT (Minimum at 100-m) — 27.8 dB at 100 MHz; 19.8 dB at 250 MHz; 12.9 dB at 550 MHz PS-NEXT (Minimum at 100-m) — 44.3 dB at 100 Mhz; 38.3 dB at 200 MHz; 33.2 dB at 350 MHz Rating Temperature Voltage — 75°C; 300 V Return Loss (Minimum at 100-m) — 20.1 dB at 100 Mhz; 17.3 dB at 250 Mhz; 14.9 dB at 550 MHz Spark test — 2.5 KV Weight — 13.65 kg/304.8-m